Ytelse for M4 (eldre)
| Modellrør | Slangemateriale | Feed Rate | Maksimal hastighet | Maks trykk | Maks temp | ||
|---|---|---|---|---|---|---|---|
| GPH | LPH | ml/min | RPM | PSI(bar) | °F(°C) | ||
| A4-*NH-T | Flex-A-Prene | .0028 - 28.5 | .0108 - 108 | 0.18 - 1800 | 125 | 125 (8.6) | 185 (85) |
| A4-*NHL-T | Flex-A-Prene | .0028 - 28.5 | .0108 - 108 | 0.18 - 1800 | 125 | 65 (4.5) | 185 (85) |
| A4-*NK-T | Flex-A-Prene | .0050 - 50.7 | .0192 - 192 | .32 - 3200 | 125 | 80 (5.5) | 185 (85) |
| A4-*NHH-T | Flex-A-Prene | .0054 - 54.0 | .0204 - 204 | .34 - 3400 | 125 | 100 (6.9) | 185 (85) |
| A4-*NHHL-T | Flex-A-Prene | .0054 - 54.0 | .0204 - 204 | .34 - 3400 | 125 | 65 (4.5) | 185 (85) |
| A4-*NL-T | Flex-A-Prene | .010 - 100.0 | .0378- 378 | .63 - 6300 | 125 | 50 (3.4) | 185 (85) |
| A4-*NP-T | Flex-A-Prene | .015 - 158.5 | .060 - 600 | 1.0 - 10000 | 125 | 30 (2.1) | 185 (85) |
| A4-*TH-T | Flex-A-Chem | .0025 - 25.4 | .0096 - 96 | 0.16-1600 | 125 | 30 (2.1) | 130 (54) |
| A4-*TK-T | Flex-A-Chem | .0054 - 54.0 | .0020 - 204 | .34 - 3400 | 125 | 30 (2.1) | 130 (54) |
| A4-*TKK-T | Flex-A-Chem | .0126 - 126 | .0477 - 477 | .08 - 8000 | 125 | 30 (2.1) | 130 (54) |
| A4-*GH-T | Flex-A-Thane | .0039 - 39.6 | .0015 - 150 | .25 - 2500 | 125 | 65 (4.5) | 130 (54) |
| A4-*GHH-T | Flex-A-Thane | .0071 - 71.0 | .0269 - 269 | .448 - 4480 | 125 | 65 (4.5) | 130 (54) |
| A4-*GK-T | Flex-A-Thane | .0028 - 28.5 | .0021 - 210 | .35 - 3500 | 125 | 65 (4.5) | 130 (54) |
| A4-*GKK-T | Flex-A-Thane | .001 - 100.0 | .0378 - 378 | .63 - 6300 | 125 | 65 (4.5) | 130 (54) |
Tilkoblinger for M4 (eldre) pumpe = *
"M" = 1/2" mannlig NPT
"B" = 1/2" slangestang
"C" = ½" – ¾" Tri-Clamp
"Q" = Rask frakobling
"MB" = 1/2 mannlig BSPT
Maksimal viskositet: 5,000 centipoise
Maksimal sugeløft: 30 fot ved havnivå (14.7 atm psi)
Elektro og kontroller
Elektrisk strømbehov: 100 til 240VAC, 50/60Hz
Motor: Brushless DC, 10,000:1 Turndown, Continuous Duty
Strømledning tilgjengelige alternativer (6 fot i lengde):
- 115VAC 50/60HZ, NEMA 5/15 plugg (USA)
- 220VAC 50/60HZ, CEE 7/V11 plugg (EU)
- 230VAC 50/60HZ, NEMA 6/15 (USA)
- 240VAC 50/60HZ, AS 3112 plugg (Australia / New Zealand)
- 230VAC 50/60HZ, BS 1363/A plugg (UK)
innganger:
- 4-20 mA – fullt konfigurerbar (kun V-modell)
- 0-10 VDC (kun V-modell)
- Frekvens / pulsinngang – fullt konfigurerbar (kun V-modell)
- Stopp/start tørr kontaktlukking (konfigurerbar for NO eller NC)
- FVS (Flow Verification System) (Flowsensor levert av andre)
utganger:
- 4-20 mA utgang – fullt konfigurerbar (kun V-modell)
- Frekvensutgang (åpen kollektor) (kun V-modell)
- Fire (4) alarmutganger – Programmerbar. (kun V-modell)
Materialer for konstruksjon
Pumpehode: Valox® (PBT)
Pumpehodedeksel: Polykarbonat, med permanent forseglet motorakselstøtte i bronsehylselager.
Dekkskruer: Rustfritt stål, polypropylenhette.
Valsemontering: Rotor – Valox, Valser – Nylon.
Motoraksel: Forkrommet stål
TFD-sensor: Hastelloy C
Strømledning: 3 ledere, SJTW-A vanntett
Monteringsbraketter: 316 rustfritt stål (standard og utvidet)
Kapsling: NEMA 4X (IP66) Pulverlakkert aluminium
Rørkoblinger: PVDF (del av rørmontasjen)
Alternativer for rørmontering
Flex-A-Prene® – Et utmerket materiale for de fleste vannbehandlingsapplikasjoner. Kjemisk motstandsdyktig mot 25 % natriumhypokloritt, 30 % svovelsyre, 30 % fluorkiselsyre, jernklorid, alun og mange andre.
Flex-A-Chem® – Dette materialet består av en ytre Norprene-jakke med en indre liner som er praktisk talt upåvirket av syrer, baser, salter, ketoner og alkoholer.
Flex-A-Thane®-rør – Dette polyuretanmaterialet kan brukes med en rekke kjemikalier, inkludert olje- og vannbaserte polymerer, drivstoff og smøremidler og mange andre.
Flex-A-Prene®-, Flex-A-Chem®- og Flex-A-Thane®-slanger oppfyller FDA 21 CFR, 117.2600 kriterier for matforedling.
Dimensjoner og vekter
Maksimal totale dimensjoner: 8.25" B x 10.75" H x 13.25" D (20.9 B x 27.3 H x 34.5 D cm)
Produktvekt: 25.4 Lb. (11.5 kg)
Omtrentlig forsendelsesdimensjoner: 16" B x 17" H x 22" D (40.5 B x 43 H x 56 D cm)
Omtrentlig fraktvekt: 35 lb. (16.0 kg)
Byråoppføringer
CE
Cetlus
RoHS
NSF 61 Oppført